cie

e-ILV

The e-ILV provides free access to all the terms and definitions contained in the international standard CIE S 017:2020 ILV: International Lighting Vocabulary, 2nd edition.

To search for another term please use  "Back to the list" to return to the main page or the e-ILV.

For the complete set of terms and definitions CIE S 017:2020 can be purchased from the CIE Webshop. Members of a CIE National Committee or Associate National Committee have access to a 66,7 % discount on the purchase price of the standard.

For advice on CIE Publications contact helpdesk@cie.co.at. Note the CIE Helpdesk cannot assist with technical enquiries.

17-29-071

room index

installation index

K

quotient of the sum of the areas of the working plane and the plane of the luminaires and the sum of the area of the walls bounded by the working plane and the plane of the luminaires, used in the calculation of the utilization factor or utilance

Note 1 to entry: The room index is expressed by the formula



where a and b are the dimensions of the sides of the room and h the mounting height, that is the distance between the working plane and the plane of the luminaires.

Note 2 to entry: See also "ceiling cavity index" and "floor cavity index".

Note 3 to entry: The room index has unit one.

Note 4 to entry: This entry was numbered 845-09-55 in IEC 60050-845:1987.

Note 5 to entry: This entry was numbered 17-1121 and 17-587 in CIE S 017:2011.

Publication date: 2020-12
Copyright © CIE 2020. All Rights Reserverd.