cie

17-21-070

photon radiance dose

Lp,t; Lt

time integral of photon radiance, Lp, over a given duration, Δt

Note 1 to entry: The corresponding radiometric quantity is "radiance dose". The corresponding photometric quantity is "luminance dose".

Note 2 to entry: The photon radiance dose is expressed in metre to the power minus two per steradian (m−2·sr−1).

Note 3 to entry: This entry was numbered 17-932 in CIE S 017:2011.

Publication date: 2020-12